PRODUCTS

DEUK YOUNG

Deuk Young Co., Ltd. promises the best products and services based on accumulated experience.

PRODUCT
Non-Conductive Water Blocking Tape
- Double Layer

PRODUCT INTRODUCTION

Non-Conductive Water Blocking Tape - Double Layer
Code Thickness(mm) Weight(g/m2) Absorption Statues Product Type Link
DYN200 0.2 85 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN200) - Single Layer

Item

Unit

DYN200

Test Method

Typical value

Thickness

0.22

ISO 9073-2

Mass Per Unit Area

g/㎡

85

ISO 9073-1

Tensile strength

N/㎝

35

ISO 9073-3

Elongation

%

10

ISO 9073-3

Swelling Speed

㎜/1min

6

DY Method

Swelling Height

㎜/3min

10

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYN220S 0.22 70 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN220S) - Single Layer

Item

Unit

DYN220S

Test Method

Typical value

Thickness

0.22

ISO 9073-2

Mass Per Unit Area

g/㎡

72

ISO 9073-1

Tensile strength

N/㎝

38

ISO 9073-3

Elongation

%

13

ISO 9073-3

Swelling Speed

㎜/1min

9

DY Method

Swelling Height

㎜/3min

11

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYN250 0.25 85 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN250) - Single Layer

Item

Unit

DYN250

Test Method

Typical value

Thickness

0.25

ISO 9073-2

Mass Per Unit Area

g/㎡

85

ISO 9073-1

Tensile strength

N/㎝

40

ISO 9073-3

Elongation

%

11

ISO 9073-3

Swelling Speed

㎜/1min

7

DY Method

Swelling Height

㎜/3min

12

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYN250S 0.25 85 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN250S) - Single Layer

Item

Unit

DYN250S

Test Method

Typical value

Thickness

0.25

ISO 9073-2

Mass Per Unit Area

g/㎡

85

ISO 9073-1

Tensile strength

N/㎝

35

ISO 9073-3

Elongation

%

11

ISO 9073-3

Swelling Speed

㎜/1min

8

DY Method

Swelling Height

㎜/3min

14

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYN300 0.3 120 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN300) - Single Layer

Item

Unit

DYN300

Test Method

Typical value

Thickness

0.30

ISO 9073-2

Mass Per Unit Area

g/㎡

120

ISO 9073-1

Tensile strength

N/㎝

45

ISO 9073-3

Elongation

%

13

ISO 9073-3

Swelling Speed

㎜/1min

8

DY Method

Swelling Height

㎜/3min

15

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYN300S 0.3 115 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN300S) - Single Layer

Item

Unit

DYN300S

Test Method

Typical value

Thickness

0.30

ISO 9073-2

Mass Per Unit Area

g/㎡

115

ISO 9073-1

Tensile strength

N/㎝

46

ISO 9073-3

Elongation

%

12

ISO 9073-3

Swelling Speed

㎜/1min

12

DY Method

Swelling Height

㎜/3min

20

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYN300S2T 0.3 100 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN300S2T) - Single Layer

Item

Unit

DYN300S2T

Test Method

Typical value

Thickness

0.30

ISO 9073-2

Mass Per Unit Area

g/㎡

100

ISO 9073-1

Tensile strength

N/㎝

40

ISO 9073-3

Elongation

%

12

ISO 9073-3

Swelling Speed

㎜/1min

13

DY Method

Swelling Height

㎜/3min

20

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYN300SH 0.3 115 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN300SH) - Single Layer

Item

Unit

DYN300SH

Test Method

Typical value

Thickness

0.30

ISO 9073-2

Mass Per Unit Area

g/㎡

115

ISO 9073-1

Tensile strength

N/㎝

50

ISO 9073-3

Elongation

%

12

ISO 9073-3

Swelling Speed

㎜/1min

16

DY Method

Swelling Height

㎜/3min

22

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYN300TH 0.3 95 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN300TH) - Single Layer

Item

Unit

DYN300TH

Test Method

Typical value

Thickness

0.30

ISO 9073-2

Mass Per Unit Area

g/㎡

95

ISO 9073-1

Tensile strength

N/㎝

32

ISO 9073-3

Elongation

%

8

ISO 9073-3

Swelling Speed

㎜/1min

18

DY Method

Swelling Height

㎜/3min

21

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYN350L 0.3 135 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN350L) - Single Layer

Item

Unit

DYN350L

Test Method

Typical value

Thickness

0.35

ISO 9073-2

Mass Per Unit Area

g/㎡

135

ISO 9073-1

Tensile strength

N/㎝

45

ISO 9073-3

Elongation

%

15

ISO 9073-3

Swelling Speed

㎜/1min

8

DY Method

Swelling Height

㎜/3min

18

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYN350S 0.3 85 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN350S) - Single Layer

Item

Unit

DYN350S

Test Method

Typical value

Thickness

0.35

ISO 9073-2

Mass Per Unit Area

g/㎡

90

ISO 9073-1

Tensile strength

N/㎝

50

ISO 9073-3

Elongation

%

12

ISO 9073-3

Swelling Speed

㎜/1min

9

DY Method

Swelling Height

㎜/3min

12

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYN400L 0.4 145 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN400L) - Single Layer

Item

Unit

DYN400L

Test Method

Typical value

Thickness

0.40

ISO 9073-2

Mass Per Unit Area

g/㎡

145

ISO 9073-1

Tensile strength

N/㎝

49

ISO 9073-3

Elongation

%

12

ISO 9073-3

Swelling Speed

㎜/1min

12

DY Method

Swelling Height

㎜/3min

20

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYN400S 0.4 120 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN400S) - Single Layer

Item

Unit

DYN400S

Test Method

Typical value

Thickness

0.40

ISO 9073-2

Mass Per Unit Area

g/㎡

120

ISO 9073-1

Tensile strength

N/㎝

55

ISO 9073-3

Elongation

%

12

ISO 9073-3

Swelling Speed

㎜/1min

13

DY Method

Swelling Height

㎜/3min

22

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYN600N 0.6 160 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance
04Strong Heat stability

Application

Separation, Bedding and Water blocking Between Conductor Layers
Over Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding
Over or inside of Buffer Tube

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYN600N) - Single Layer

Item

Unit

DYN600N

Test Method

Typical value

Thickness

0.48

ISO 9073-2

Mass Per Unit Area

g/㎡

160

ISO 9073-1

Tensile strength

N/㎝

55

ISO 9073-3

Elongation

%

15

ISO 9073-3

Swelling Speed

㎜/1min

14

DY Method

Swelling Height

㎜/3min

25

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DYNM300 0.3 135 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Excellent Swelling Performance From Sea Water Strong Gel Strength

Application

Separation, Bedding
Over or under Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYNM300) - Single Layer

Item

Unit

DYNM300

Test Method

Typical value

Thickness

0.31

ISO 9073-2

Mass Per Unit Area

g/㎡

135

ISO 9073-1

Tensile strength

N/㎝

34

ISO 9073-3

Elongation

%

10.5

ISO 9073-3

Swelling Speed
(Artificial Sea Water)

㎜/1min

1.0

DY Method

Swelling Height
(Artificial Sea Water)

㎜/3min

2.0

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

Artificial Sea Water + DY TEST METHOD

DYNM400 0.4 190 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Excellent Swelling Performance From Sea Water Strong Gel Strength

Application

Separation, Bedding
Over or under Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYNM400) - Single Layer

Item

Unit

DYNM400

Test Method

Typical value

Thickness

0.4

ISO 9073-2

Mass Per Unit Area

g/㎡

190

ISO 9073-1

Tensile strength

N/㎝

50

ISO 9073-3

Elongation

%

20

ISO 9073-3

Swelling Speed
(Artificial Sea Water)

㎜/1min

2.5

DY Method

Swelling Height
(Artificial Sea Water)

㎜/3min

3.0

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

Artificial Sea Water + DY TEST METHOD

DYNM450H 0.45 200 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Excellent Swelling Performance From Sea Water Strong Gel Strength

Application

Separation, Bedding
Over or under Screen Layers
Under Sheath or Jacket for Moisture Barrier and Binding

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYNM450H) - Single Layer

Item

Unit

DYNM450H

Test Method

Typical value

Thickness

0.45

ISO 9073-2

Mass Per Unit Area

g/㎡

200

ISO 9073-1

Tensile strength

N/㎝

60

ISO 9073-3

Elongation

%

10

ISO 9073-3

Swelling Speed
(Artificial Sea Water)

㎜/1min

3.0

DY Method

Swelling Height
(Artificial Sea Water)

㎜/3min

3.5

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

Artificial Sea Water + DY TEST METHOD

DYP280 0.28 125 O Nonwoven fabric + Mesh
Non-Conductive Water Blocking Tape - Double Layer

Product features

01Good Laminating Condition without Separating Film and Fabric
02High Swelling Performance

Application

For Barrier tape for jelly compound intrusions and migration

SPECIFICATION
Semi-Conductive Water Blocking Tape
(DYP280) - Single Layer

Item

Unit

DYP280

Test Method

Typical value

Thickness

0.29

ISO 9073-2

Mass Per Unit Area

g/㎡

125

ISO 9073-1

Tensile strength

N/㎝

55

ISO 9073-3

Elongation

%

12

ISO 9073-3

Swelling Speed

㎜/1min

12

DY Method

Swelling Height

㎜/3min

18

DY Method

Polyester Film Thickness

0.012

DY Method

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request