PRODUCT
Non-Conductive Water Blocking Tape
- Single Layer

PRODUCT INTRODUCTION

Non-Conductive Water Blocking Tape - Single Layer
Code Thickness(mm) Weight(g/m2) Absorption Statues Product Type Link
DSN1045 0.15 45 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN1045) - Single Layer

Item

Unit

DSN1045

Test Method

Typical value

Thickness

0.18

ISO 9073-2

Mass Per Unit Area

g/㎡

45

ISO 9073-1

Tensile strength

N/㎝

14

ISO 9073-3

Elongation

%

12

ISO 9073-3

Swelling Speed

㎜/1min

7

DY Method

Swelling Height

㎜/3min

8

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSN1045P 0.1 45 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN1045P) - Single Layer

Item

Unit

DSN1045P

Test Method

Typical value

Thickness

0.13

ISO 9073-2

Mass Per Unit Area

g/㎡

45

ISO 9073-1

Tensile strength

N/㎝

20

ISO 9073-3

Elongation

%

18

ISO 9073-3

Swelling Speed

㎜/1min

5

DY Method

Swelling Height

㎜/3min

6

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSN1050 0.15 50 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN1050) - Single Layer

Item

Unit

DSN1050

Test Method

Typical value

Thickness

0.15

ISO 9073-2

Mass Per Unit Area

g/㎡

50

ISO 9073-1

Tensile strength

N/㎝

26

ISO 9073-3

Elongation

%

15

ISO 9073-3

Swelling Speed

㎜/1min

6

DY Method

Swelling Height

㎜/3min

7

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSN1055 0.16 55 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN1055) - Single Layer

Item

Unit

DSN1055

Test Method

Typical value

Thickness

0.15

ISO 9073-2

Mass Per Unit Area

g/㎡

55

ISO 9073-1

Tensile strength

N/㎝

26

ISO 9073-3

Elongation

%

15

ISO 9073-3

Swelling Speed

㎜/1min

8

DY Method

Swelling Height

㎜/3min

10

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSN1065 0.17 65 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN1065) - Single Layer

Item

Unit

DSN1065

Test Method

Typical value

Thickness

0.16

ISO 9073-2

Mass Per Unit Area

g/㎡

65

ISO 9073-1

Tensile strength

N/㎝

30

ISO 9073-3

Elongation

%

15

ISO 9073-3

Swelling Speed

㎜/1min

10

DY Method

Swelling Height

㎜/3min

13

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSN1085 0.18 85 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN1085) - Single Layer

Item

Unit

DSN1085

Test Method

Typical value

Thickness

0.18

ISO 9073-2

Mass Per Unit Area

g/㎡

85

ISO 9073-1

Tensile strength

N/㎝

30

ISO 9073-3

Elongation

%

15

ISO 9073-3

Swelling Speed

㎜/1min

15

DY Method

Swelling Height

㎜/3min

23

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSN1085S 0.2 85 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN1085S) - Single Layer

Item

Unit

DSN1085S

Test Method

Typical value

Thickness

0.20

ISO 9073-2

Mass Per Unit Area

g/㎡

85

ISO 9073-1

Tensile strength

N/㎝

36

ISO 9073-3

Elongation

%

24

ISO 9073-3

Swelling Speed

㎜/1min

12

DY Method

Swelling Height

㎜/3min

18

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSN1100 0.25 100 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN1100) - Single Layer

Item

Unit

DSN1100

Test Method

Typical value

Thickness

0.25

ISO 9073-2

Mass Per Unit Area

g/㎡

100

ISO 9073-1

Tensile strength

N/㎝

48

ISO 9073-3

Elongation

%

32

ISO 9073-3

Swelling Speed

㎜/1min

16

DY Method

Swelling Height

㎜/3min

22

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSN1120 0.29 120 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN1120) - Single Layer

Item

Unit

DSN1120

Test Method

Typical value

Thickness

0.30

ISO 9073-2

Mass Per Unit Area

g/㎡

120

ISO 9073-1

Tensile strength

N/㎝

45

ISO 9073-3

Elongation

%

25

ISO 9073-3

Swelling Speed

㎜/1min

14

DY Method

Swelling Height

㎜/3min

24

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSN2040 0.16 40 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN2040) - Single Layer

Item

Unit

DSN2040

Test Method

Typical value

Thickness

0.20

ISO 9073-2

Mass Per Unit Area

g/㎡

40

ISO 9073-1

Tensile strength

N/㎝

24

ISO 9073-3

Elongation

%

12

ISO 9073-3

Swelling Speed

㎜/1min

7

DY Method

Swelling Height

㎜/3min

8

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSN2055 0.3 55 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN2055) - Single Layer

Item

Unit

DSN2055

Test Method

Typical value

Thickness

0.32

ISO 9073-2

Mass Per Unit Area

g/㎡

55

ISO 9073-1

Tensile strength

N/㎝

42

ISO 9073-3

Elongation

%

12

ISO 9073-3

Swelling Speed

㎜/1min

5

DY Method

Swelling Height

㎜/3min

6

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSN2055B 0.24 55 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN2055B) - Single Layer

Item

Unit

DSN2055B

Test Method

Typical value

Thickness

0.25

ISO 9073-2

Mass Per Unit Area

g/㎡

55

ISO 9073-1

Tensile strength

N/㎝

26

ISO 9073-3

Elongation

%

11

ISO 9073-3

Swelling Speed

㎜/1min

9

DY Method

Swelling Height

㎜/3min

10

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSN2070B 0.23 70 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN2070B) - Single Layer

Item

Unit

DSN2070B

Test Method

Typical value

Thickness

0.25

ISO 9073-2

Mass Per Unit Area

g/㎡

72

ISO 9073-1

Tensile strength

N/㎝

31

ISO 9073-3

Elongation

%

12

ISO 9073-3

Swelling Speed

㎜/1min

13

DY Method

Swelling Height

㎜/3min

17

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSN2085B 0.25 85 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSN2085B) - Single Layer

Item

Unit

DSN2085B

Test Method

Typical value

Thickness

0.26

ISO 9073-2

Mass Per Unit Area

g/㎡

85

ISO 9073-1

Tensile strength

N/㎝

32

ISO 9073-3

Elongation

%

12

ISO 9073-3

Swelling Speed

㎜/1min

13

DY Method

Swelling Height

㎜/3min

20

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

DSNM1120 0.2 120 O Nonwoven fabric
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive Water Blocking Tape
(DSNM1120) - Single Layer

Item

Unit

DSNM1120

Test Method

Typical value

Thickness

0.2

ISO 9073-2

Mass Per Unit Area

g/㎡

122

ISO 9073-1

Tensile strength

N/㎝

21

ISO 9073-3

Elongation

%

20

ISO 9073-3

Swelling Speed
(Artificial Sea Water)

㎜/1min

1.8

DY Method

Swelling Height
(Artificial Sea Water)

㎜/3min

2.1

DY Method

Maximum Processing Temperature

230

DY Method

Maximum Service Temperature

90

IEC 216

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request

Artificial Sea Water + DY TEST METHOD

DSN2090 0.22 90 O Nonwoven fabric + Film
Non-Conductive Water Blocking Tape - Single Layer

Product features

01Stable Density, Thickness & Tensile Strength
02Keep working environment clean
03Excellent Swelling Performance & Heat stability
04No powder drop Extreme smooth surface
05Strip jacket off with no lamination

Application

Separation and Water blocking Over Screen Layers
Between Conductor Layers
Under Sheath or Jacket
Over or inside of Buffer Tube

SPECIFICATION
Non-Conductive PET Laminated Water Blocking Tape
(DSN2090) - Single Layer

Item

Unit

DSN2090

Test Method

Typical value

Thickness

0.22

ISO 9073-2

Mass Per Unit Area

g/㎡

90

ISO 9073-1

Tensile strength

N/㎝

40

ISO 9073-3

Elongation

%

14

ISO 9073-3

Swelling Speed

㎜/1min

12

DY Method

Swelling Height

㎜/3min

17

DY Method

Polyester Film Thickness

0.012

DY Method

Moisture content

%

5

KS K0349

Remarks

Standard Core Inside Diameter : Ф76 or As customer’s request

Standard Pad Outside : As customer’s request